The British Council for Offices starts planning at 10 m² (108 sq ft) of net internal area per workspace, then divides by the share of staff in on a peak day: at 66% that is about 15 m² (161 sq ft) per employee. The fire-code 6 m² is a different number: an escape ceiling, not a space allowance.
Five figures, five meanings
Most pages that answer this question quote one number and leave out which kind it is. Five figures circulate, they are three different kinds of number, and they differ by a factor of more than two for good reasons.
| Figure | In sq ft | What it is | Source |
|---|---|---|---|
| 10 m² per workspace | 108 | Design density: net internal area given to each workspace | British Council for Offices starting density, as reported by CIBSE Journal (October 2022) |
| 12.5 m² per person | 135 | Effective density: 10 m² at 80% peak utilisation | The BCO's earlier assumption (CIBSE Journal; BCO release, July 2025) |
| 15 m² per person | 161 | Effective density: 10 m² at 66% utilisation | BCO release, 10 July 2025 |
| 16.7 m² per person | 180 | Effective density: 10 m² at 60% utilisation | Proposed in the BCO's 2022 position paper (CIBSE Journal) |
| 6 m² per person | 65 | Fire-code floor space factor for offices, an escape ceiling | Approved Document B volume 2, Table D1 |
The first four are one calculation with different utilisation inputs. The last is a different thing entirely.
Why the figures conflict
The disagreement comes from mixing three things that all use "square metres per person": a design allowance, an effective allowance and a measurement. A reader who sees 10 m² on one page and 15 m² on another has found the same BCO method run at two utilisation rates, not two competing standards.
Design density is how much net internal area each workspace gets. Effective density is that area divided by the share of people who are in on a peak day, because a building with 80 employees and 53 seats at peak needs the area for staff, not for seats. The BCO's own measured data is a third kind: CIBSE Journal quotes 14.8 m² per desk in 2001 and 9.6 m² in 2018 from the BCO's Office Occupancy: Density and Utilisation report, and a survey it reports, of 113 paired responses, found current densities of 9.0 m² per desk, with a spread of 2.4 m² either way.
Two more things blur the numbers. Net internal area (NIA) is the usable floor, leaving out shared cores such as stairs, lifts and toilet blocks, while gross internal area counts everything inside the walls, so the same office has a smaller NIA figure than GIA figure. Interaction's summary of the BCO guidance, one of the pages that ranks for this question, gives 10 to 12 m² per person without saying which area it means. And per desk and per person are not the same: CIBSE Journal notes that metres per occupant had become the more relevant measure than metres per desk once desks were shared.
How to calculate office space per person
Divide the design density by peak utilisation, then multiply by the number of employees. The inputs are the design density (10 m² unless your fit-out needs more), the share of employees in on your busiest day, and your headcount.
Worked example: 80 employees, 10 m² per workspace.
| Peak utilisation | Space per employee | Seats at peak | Net internal area | In sq ft |
|---|---|---|---|---|
| 80% | 12.5 m² | 64 | 1,000 m² | 10,764 |
| 66% | 15.2 m² | 53 | 1,212 m² | 13,047 |
| 60% | 16.7 m² | 48 | 1,333 m² | 14,352 |
The BCO release gives the 66% case as 15 m² per occupant, which this arithmetic reproduces to the nearest metre (10 ÷ 0.66 = 15.15). Moving from 80% to 66% adds about 21% to the area. The 60% case, the 2022 proposal, adds a third.
Measure the peak instead of assuming it. If the busiest day is usually a Tuesday, count the people through the door on a few Tuesdays. The utilisation in a lease or a fit-out brief should come from a count, not from a survey of intentions: the research CIBSE Journal reports found pre-pandemic occupancy of 81% in a survey against 70% in interviews, and expected future occupancy of 68% in the survey against 45% in the interviews.
What the BCO changed, and when
The BCO's position has moved towards more space per person. The 8 m² high-density allowance has gone, the starting density stayed at 10 m², and the utilisation divisor fell from 80% to 66%.
| When | Figure | What happened |
|---|---|---|
| 2001 | 14.8 m² per desk | Average measured density (BCO data, via CIBSE Journal) |
| 2018 | 9.6 m² per desk | Average measured density; the BCO's 2018 base level was 8 m² per person (Interaction) |
| 2022 | 8 m² withdrawn; 16.7 m² proposed | Position paper: high-density figure withdrawn, 60% utilisation proposed (CIBSE Journal) |
| February 2023 | 10 to 12 m² per person | Recommendation as summarised by Interaction |
| July 2025 | 15 m² per occupant | New report: 66% utilisation, up from 12.5 m²; 80% "may no longer be fit for purpose" |
These figures are as reported by CIBSE Journal, Interaction and the BCO's 2025 release. The BCO's Guide to Specification and its 2022 position paper are sold publications and were not read in full for this guide, so check the edition your lease or brief cites.
Fire occupancy is a different number
The 6 m² in Approved Document B is a count of the people an office floor may be planned to evacuate, and the BCO's own release describes the escape-route figure as fixed by legislation. In the UK, Table D1 sets the office floor space factor at 6.0 m² per person; in the US the 2024 International Building Code lists 150 gross square feet (13.9 m²) for business areas. Both are ceilings for exits, stairs and sprinklers, set to be safe in a fire, and they say nothing about how many desks fit.
Use it for the question it answers. A 900 m² floor at 6.0 m² is planned for 150 people however many desks it holds, and a floor designed at 15 m² per employee holds about 60 staff but still needs exits for 150. The occupancy calculator works out the fire-code figure from a floor area, checks it against the exit widths, and shows which of the two sets the limit.
The legal minimum for a workroom
UK law sets a floor for how crowded a workroom may be, but not a design density. Regulation 10 of the Workplace (Health, Safety and Welfare) Regulations 1992 says every room where people work must have sufficient floor area, height and unoccupied space for health, safety and welfare. For workplaces that were subject to the Factories Act 1961 and have not been newly built, modified or extended, Schedule 1 Part I gives a figure: 11 cubic metres per person, not counting space more than 4.2 m above the floor.
At a 2.7 m ceiling that is about 4.1 m² of floor per person, so a layout that follows the BCO's 10 m² clears it with room to spare. This guide does not state the guidance for newer workplaces, because the HSE approved code was not read for it. Take that from the code, or from a surveyor.
What these figures do not tell you
These are planning ratios, not advice on a lease, a fit-out or a safety case. They do not say how many meeting rooms, phone booths or breakout areas a team needs, and the BCO's rise to 10 to 12 m² is partly about those, as Interaction reports it. They count staff, not visitors: CIBSE Journal notes that non-desk floors with visitor footfall may need 100 to 120% or more.
The most useful number is the one nobody can quote for you: the peak number of people in your own building. A door counter, a week of tallies and the busiest day are worth more than any standard, because the standard only turns your peak into an area.
Frequently asked questions
How much office space per person do you need?
Start from 10 m² (108 sq ft) of net internal area per workspace, the British Council for Offices' starting density, then divide by peak utilisation to get space per employee. At the BCO's 2025 figure of 66% that is about 15 m² (161 sq ft); at the older 80% it is 12.5 m² (135 sq ft). A team that is always in needs nearer 10 m².
How many square feet per person in an office?
Multiply the square metres by 10.764. A 10 m² workspace is 108 sq ft, the 12.5 m² effective density is 135 sq ft, the 15 m² figure is 161 sq ft and 16.7 m² is 180 sq ft. The fire-code business factor, 150 gross sq ft per person in the 2024 International Building Code, is 13.9 m² and is not a design density.
What is the difference between design density and effective density?
Design density is the net internal area given to each workspace, 10 m² in the BCO's starting figure. Effective density is the area per employee once not everyone is in at once: design density divided by peak utilisation. 10 m² at 80% is 12.5 m² per person; at 66% it is about 15 m²; at 60% it is 16.7 m².
Is 8 m² per person still the BCO standard?
No. CIBSE Journal reported in October 2022 that the high-density occupancy of 8 m² net internal area per work setting had been withdrawn, and Interaction's summary of the BCO's 2023 guidance gives 10 to 12 m² per person. The BCO also says densities below 8 m² are more likely to cause comfort and wellbeing problems.
Why do sources quote 10, 12.5, 15 and 16.7 m² per person?
They answer different questions. 10 m² is the design density per workspace. 12.5, 15 and 16.7 m² are effective densities per employee, the same 10 m² divided by 80%, 66% and 60% utilisation. Most disagreement between sources is a different utilisation assumption, not a different measurement of the same thing.
Is the fire-code 6 m² per person the space each worker needs?
No. Approved Document B's floor space factor for offices, 6.0 m² per person, sets the number of people a floor may be planned to evacuate. A 900 m² floor is planned for 150 people however many desks it holds. Using it as a desk allowance would give each person 40% less space than the BCO's own 10 m² starting point.
What does UK law say about minimum space per worker?
Regulation 10 of the Workplace (Health, Safety and Welfare) Regulations 1992 requires every room where people work to have sufficient floor area, height and unoccupied space. For older workplaces Schedule 1 Part I sets 11 cubic metres per person, not counting space more than 4.2 m above the floor. Neither is a planning density.
What utilisation should I assume for hybrid working?
The BCO's 2025 report calls 66% a realistic but conservative figure and says the long-standing 80% may no longer be fit for purpose. CIBSE Journal cites average office utilisation of 40 to 60%. Count your own peak day: it is the only number that applies to your building, and it changes the area you need by a fifth or more.
People also search for
More in counting and tallying
How to count store foot traffic and work out the conversion rateWho to count and who to leave out, sample hours matched hour by hour to the till, conversion per person and per group, and how big a change has to be before it is real.Published · 11 min read
How to do a manual traffic countThe class schemes compared (FHWA's 13, the DfT's census classes, PNG's 0-12), why 15-minute intervals, a tally sheet layout, and the peak hour factor worked through.Published · 14 min read
Cycle counting: how often to count A, B and C itemsHow to rank items by value, why no rulebook fixes the A-item frequency, the daily workload worked out, and the tolerance and recount rules ERP systems use.Published · 16 min read
How to count a flock of birdsBlocks, tens, and why the number to report is the most seen at one time.Updated · 9 min read
Types of counters explainedSynchronous vs asynchronous, mod-N, ring and Johnson, industrial and PLC counters, plus mechanical and software counters.Updated · 11 min read
Tally marks explainedGroups of five, the five-bar gate, and why the convention has survived for centuries.Updated · 19 min read